01.06.2021 / Oil-Lubricated Vacuum Pump Maintenance Instructions

  1. Before commissioning your pump, always read the user manual carefully.

  2. Never operate the pump without oil. The initial operating oil may already be supplied inside the pump. If the pump is supplied without oil, fill it with the appropriate oil up to approximately 3/4 of the recommended oil level.

Not every synthetic or mineral oil is suitable for vacuum pumps. Using an unsuitable oil may significantly reduce the service life of the vanes and can lead to mechanical failures. For information about the correct oil specifications, please contact us at +90 216 452 4576.

  1. The pump power supply is single-phase (230 VAC) or three-phase (400 VAC). Before making any electrical connection, always check the motor nameplate on the pump.

Make sure that the Star (Y) or Delta (Δ) connection is made correctly.

  1. If your pump draws a current (A) higher than the rated current specified on the nameplate, stop the pump and check the electrical connections before continuing operation. Otherwise, the electric motor may be damaged or burned out.

For three-phase motors, always measure and verify the current (A) drawn by each phase individually.

  1. To ensure efficient operation and extend the service life of your pump, the recommended maintenance kits must be used regularly.

  2. Maintenance kit replacement is relatively easy. Maintenance kits are available from us. For maintenance kits, please contact us at +90 216 452 4576.

GENERAL MAINTENANCE SCHEDULE

Every 24 hours: Check the pump oil level.

Every 50 hours: Clean the pump air filter.

Every 500 hours: Replace the pump oil. Topping up the existing oil is not recommended; the oil should be completely replaced.

Every 1,000 hours: Replace the pump oil filter.

Every 2,000 hours: Replace all pump filters and filter O-ring sets. (Minor Maintenance)

Every 10,000 hours: Replace the pump vanes, bearings, seals, all filters, and O-ring sets. (Major Maintenance)

The service intervals above are intended for normal dry and clean processes. These intervals may vary depending on operating conditions. Applications involving high levels of dust, water vapor, moisture, gases, composite resins, chemical gases, paints, or other contaminants may require more frequent maintenance.

 

15.08.2019 / What Is Vacuum?

The word vacuum originates from the Latin word vacuus, meaning empty space, and is used to describe pressures below atmospheric pressure.

In other words, a vacuum is created by removing molecules from a confined volume that is initially at atmospheric pressure. As illustrated below, as the vacuum level increases, the number of gas molecules decreases logarithmically. In laboratory environments, pressures down to approximately 10⁻¹⁴ mbar can be achieved; however, zero pressure, or a perfect vacuum, is unattainable.

Vacuum can be defined as a confined volume filled with gas at a pressure below atmospheric pressure. At sea level and at a temperature of 22 °C, atmospheric pressure corresponds to approximately 2.5 × 10²⁵ gas molecules per cubic meter. Therefore, the term vacuum is used to describe environments in which the number of gas molecules and consequently the pressure are below atmospheric conditions.

Another definition describes vacuum as the process of progressively reducing atmospheric pressure, approximately 760 mmHg (Torr), using vacuum pumps. In other words, vacuum can be described as the removal or condensation of the molecules responsible for creating the pressure of a gas or air.

Various units are used to express vacuum levels, including mbar, bar, Torr, Pa, and inHg. Similar to compressed-air systems, vacuum pressure can be expressed as either absolute pressure (a) or gauge pressure (g).

A vacuum is created when the air pressure within a confined area is reduced below atmospheric pressure. Since the pressure in the vacuum area is lower than the surrounding atmospheric pressure, air naturally flows into the evacuated area. If an object is brought close to the air-flow path, it can be drawn toward the vacuum due to the pressure difference, creating a holding force.

Vacuum can be artificially generated, while naturally occurring vacuum conditions can also be observed in certain environments. A vacuum created by reducing the density of gas molecules within a volume can be considered an artificial vacuum, while the near-vacuum conditions naturally existing in outer space can be given as an example of a natural vacuum.

Pressure and vacuum are expressed using the same fundamental units. In vacuum applications, Torr or Pascal (Pa) are commonly used.

The lowest vacuum levels achievable under laboratory conditions can reach approximately 10⁻¹⁵ atm. At such an extremely low pressure, the number of atoms present in one cubic meter is drastically reduced. The closest approximation to a perfect vacuum is found in outer space, where the density of matter can be extremely low.

​

Vacuum ranges can generally be classified as follows:

  • Low Vacuum: 750 Torr – 1 Torr

  • Medium Vacuum: 1 Torr – 10⁻³ Torr

  • High Vacuum: 10⁻³ Torr – 10⁻⁶ Torr

  • Very High Vacuum: 10⁻⁶ Torr – 10⁻⁹ Torr

  • Ultra-High Vacuum: 10⁻⁹ Torr – 10⁻¹² Torr

  • Extremely High Vacuum: 10⁻¹² Torr – 10⁻¹⁶ Torr

ADUVAC VAKUM MÜHENDİSLİK HİZMETLERİ SAN. VE TİC. LTD. ŞTİ.

Head Office: Soğanlık Gümüşpınar Mah. Yeniçağ Cad. No:9A  Kartal-İstanbul -Turkey

Technical Service / Warehouse: Soğanlık Gümüşpınar Mah. Yeniçağ Cad. No:9A/B  Kartal-İstanbul -Turkey

Phone: +90 216 4524576  (PBX) I Web: www.aduvac.com 

E-mail: aduvac@aduvac.com  ǀ  satis@aduvac.com

ADUVAC 20.YIL
ADUVAC QR

            ADUVAC © 2026 - Copyrights 

bottom of page